Self-Regulating Medium Temp Heating Cable 8-1CT
Chromalox SRM/E self-regulating heating
cable provides safe, reliable heat tracing for
process temperature maintenance and freeze
protection of pipes, valves, tanks and similar
applications. Constructed of industrial grade
16 AWG buss wire with metal braid and optional
overjacketing, SRM/E ensures operating
integrity in most hostile industrial environments.
The 420°F (215°C) maximum exposure
temperature rating allows steam cleaning of
process equipment with up to 300 psig steam
NOTE: A single quantity purchase equals 1ft of cable. Adding multiple
quantity of the same cable will add to the overall length of the
product.
For example: quantity of 10 = 10ft long cable.
NAME
|
Self regulating Medium Temp Heating Cable
...
|
APPROX. SIZE
|
0.375in
W x 0.125in H
/ 9.525mm W x 3.125mm H
|
Part#
|
388148 |
PROCESS TEMP MAINTENANCE
|
302ºF/150ºC
|
Agency Approval
|
ATEX, IECEX, FM, UL, CSA
|
MAXIMUM CONT TEMP, POWER OFF
|
420ºF/215ºC
|
VOLTS
|
120V
|
WATTS/FT
|
8W/FT
|
CABLE CONSTRUCTION
|
Twin 16 AWG Copper Buss Wire
|
HEATING CABLE LENGTH
|
Sold per Linear Foot, 1FT =1QTY
|
COLOR
|
Metallic
|
CONDUCTOR MATERIAL
|
Copper
|
MINIMUM BEND RADIUS
|
1.125in
/ 28.575mm
|
Applications
- Self-Regulating, Energy Efficient
- For Use on Metallic Pipes Only
- Industrial Process Maintenance
- Industrial Freeze Protection Application
- Freeze Protection of Fire Protection System Piping
FEATURES
-
Energy efficient, self-regulating SRM/E uses
less energy when less heat is required.
- Easy to install, SRM/E can be cut to any
length (up to max. circuit length) in the field.
- Field splices can be performed easily in minutes
with no scrap or wasted cold sections.
- With lower installed cost than steam tracing,
SRM/E features less maintenance expense
and downtime.
- SRM/E can be overlapped without burnout,
which simplifies heat tracing of in-line process
equipment such as valves, elbows and
pumps. Because SRM/E is self-regulating, overtemperature
conditions are minimized.
- Chromalox termination, splice, tee and end
seal kits reduce installation time.
CONSTRUCTIONS
- Twin 16 AWG Copper Buss Wire - Provide reliable electrical current capability
- Semiconductive Polymer Core Matrix - "Self-Regulating" competent of cable, its electrical resistance varies with temperature. As process temperature drops, the core's heat output increases; as process temperature rises, the heat output decreases
- High Temperature Fluoropolymer Jacket - Flame retardant, electrically insulates the matrix and provides corrosion resistance.
- Metallic Braid - Provides additional mechanical protection in any environment and a positive ground path
- High Temperature Fluoropolymer Overjacket - Corrosion resistant, flame retardant overjacket is highly effective in hostile, aqueous and chemically active environments. It also protects against abrasion and impact damage
WARNING - A ground fault protection device is required by NEC to minimize the danger of fire if the heating cable is damaged or improperly installed. A minimum trip level of 30mA is recommended to minimize nuisance tripping
Approvals:
ATEX and IECEX Exe IIGb, Factory Mutual (FM) approved for ordinary areas. UL Listed, CSA Certified for ordinary areas. UL listed for freeze protection of fire protection system piping. FM approved for hazardous (classified) areas when used with U Series, DL and EL accessories:
- Class I, Div. 2, Groups B, C, D (gases vapors)
- Class II, Div. 2, Groups F,G (combustible dust)
- Class III, Div. 2 (easily ignitable fibers and filings)
- 5 and 8 Watt Rated T3 Temperature Class
- 10, 15, 20 Watt Rated T2D Temperature Class
CSA Certified for hazardous (classified) areas when used with DL and U Series accessories:
- Class I, Div. 2, Groups A, B, C, D
- Class II, Div. 2, Group F, G
- Rated T3 Temperature Class
- ATEX and IECEX Exe IIGb
- IIG Exe II
Note 1 Exception - Cable Surface Temperature shall not exceed 190ºC in Class II, Div. 2, Group F; 165ºC in Class II, Div. 2, Group G.
|
|
|